Mobile electrician v1.5
Requirements: Android 1.6+
Overview: The program is designed for calculations that are used in the daily work of an electrician.
Requirements: Android 1.6+
Overview: The program is designed for calculations that are used in the daily work of an electrician.
The program is designed for calculations that are used in the daily work of an electrician.
The program helps you calculate:
Current, voltage, power and resistance by Ohm’s law.
Total capacitance at parallel and connected in series capacitors.
Total resistance at parallel and connected in series resistors.
Resistance capacitances AC.
Calculation capacitor to start the three phases motor in single phase supply.
Calculation of the voltage divider
Calculation of the resistor for LED
Conductor resistance as a function of the conductor material, length, cross-section and temperature.
Allowable continuous current for wires and cables on the table PBU (Rules of electrical facilities maintenance).
Cross-section wire or cables on the heating of and voltage losses on the set parameters (wires and cables from table PBU).
Calculation of the cross-section and the circuit breaker to connect the motor.(wires and cables from table PBU).
Fuse and wire to replace the burned-out fuse.
Minimum short circuit current.
Loss of voltage in a conductor for a given length, cross-section
and current, taking into account the ambient temperature and conductor material.
Total leakage current for the differential current tripping the RCD.
Electric heating element nichrome wire.
Translate Diameter and the cross section.
Conversion: Active power – Total power.
Translations AWG (American Wire gauge) in inches, millimeters, millimeters square and back.
Conversion of units of temperature.
Calculation power generator to house
The program helps you calculate:
Current, voltage, power and resistance by Ohm’s law.
Total capacitance at parallel and connected in series capacitors.
Total resistance at parallel and connected in series resistors.
Resistance capacitances AC.
Calculation capacitor to start the three phases motor in single phase supply.
Calculation of the voltage divider
Calculation of the resistor for LED
Conductor resistance as a function of the conductor material, length, cross-section and temperature.
Allowable continuous current for wires and cables on the table PBU (Rules of electrical facilities maintenance).
Cross-section wire or cables on the heating of and voltage losses on the set parameters (wires and cables from table PBU).
Calculation of the cross-section and the circuit breaker to connect the motor.(wires and cables from table PBU).
Fuse and wire to replace the burned-out fuse.
Minimum short circuit current.
Loss of voltage in a conductor for a given length, cross-section
and current, taking into account the ambient temperature and conductor material.
Total leakage current for the differential current tripping the RCD.
Electric heating element nichrome wire.
Translate Diameter and the cross section.
Conversion: Active power – Total power.
Translations AWG (American Wire gauge) in inches, millimeters, millimeters square and back.
Conversion of units of temperature.
Calculation power generator to house
The ability to save the result of calculation cross-section in text format, and then view.
For each calculation (except to Ohm’s law) is given a separate information.
English, Ukrainian and Russian interface.
For each calculation (except to Ohm’s law) is given a separate information.
English, Ukrainian and Russian interface.
If you like the application, please rate it.
More Info:
Code: